Tiaano ventured and developed a Electrolytic Scale Remover (ElSr); without adding chemicals, it generates disinfectant insitu and remove the scale by electrolytic operation - mitigate the scaling, corrosion, bio-fouling & bacterial infection in cooling tower Water distribution system.  ElSr produces Oxidants in the water; Oxidants prevents the Corrosion, Bio-fouling, Scaling, Micro-Organism growth & spread of airborne bacteria. 

Scale / Slime fouling on Condenser results reduction in heat transfer.  One mm thick of scaling  will cause 30% more energy consumption.  Because of Ionization in ElSr, scale precipitation occurs; once the scale precipitated, it never adheres to the Condensers / cooling tower Water distribution system – it leads no further scale build up, slowly the existing scales also peels out in due course.  Resulting maintain ‘DELTA T’ as it is when you used descaling agent or improves ‘DELTA T’. Thus Electricity is saved. 

Passing DC current from positive element to the negative element, it creates high pH in the vicinity of the negative.  High pH causes scale to be deposited in the reactor.  The water is not soft at the outlet of the ElSr, but the scale forming ions has been reduced to a level that prevents the precipitation in cooling tower Water distribution system. ElSr will precipitate all scale forming ions, not just magnesium and calcium but other ions that are susceptible to dropping out the liquid at high pH Viz., Silica, Ferum, Manganese etc.
 The reaction in the chamber is   Cl -   +   H +   à   HCl       and then       HCl + HCl à  Cl2 + H2
 ElSr removes suspended solids automatically and continually through its inbuilt micron filter.   Savings in feed water, because reduction in water bleed.  Modular system is designed and available according to the cooling tower chiller capacity like 200 TR, 300 TR, 400 TR, 600 TR, 800 TR, 900 TR, 1200 TR & 1600 TR.  For more details, please visit our website http://www.scaleseparator.com




With Warm Regards,
V.   P.    Jeyakumar.
Managing  Director.

HP: +91 91766 25082   Off. Ph - 9444 56 9900   Skype  ID: tiaanojk
Ph: +91 44 2278 1148  Fax: 2278 1362   Web :  www.tianode.com
E-mail :
managingdirector@tiaano.com  | tianode@gmail.com    
           


Ti     Anode    Fabricators     Private     Limited.
#  -  48,  Noothanchary,  Madambakkam, Chennai - 126, INDIA.
GSTIN: 33AABCT9790N1ZN PAN: AABCT 9790N AADHAR: 7522 0783 3933 



No comments:

Post a Comment

Removal of scale in Cooling Tower circuit by chemical free scale separation- 'Electrolytic Scale Remover'

Tiaano ventured and developed a Electrolytic Scale Remover (ElSr).  It removes the scale by electrolytic operation with out adding chemica...