Wednesday, 3 January 2018

Removal of scale in Cooling Tower circuit by chemical free scale separation- 'Electrolytic Scale Remover'

Tiaano ventured and developed a Electrolytic Scale Remover (ElSr).  It removes the scale by electrolytic operation with out adding chemicals (Zero Chemical).   It generates Oxidants in the water; Oxidants mitigate the Corrosion, Bio-fouling, Micro-Organism growth, Scaling, & spread of airborne bacteria. 

Passing DC current from positive element to the negative element, it creates high pH in the vicinity of the negative.  High pH causes scale to be deposited in the reactor.  The water is not soft at the outlet of the ElSr, but the scale forming ions has been reduced to a level that prevents the precipitation in Water distribution system.   ElSr will precipitate all scale forming ions, not just magnesium and calcium but other ions that are susceptible to dropping out the liquid at high pH Viz., Silica, Ferum, Manganese etc.

Scale / Slime fouling on Condenser results reduction in heat transfer.  One mm thick of scaling  will cause 30% more energy consumption.  Because of Ionization in ElSr, scale precipitation occurs; once the scale precipitated, it never adheres to the Condensers / cooling tower Water distribution system – it leads no further scale build up, slowly the existing scales also peels out in due course.  Resulting maintain ‘DELTA T’ as it is when you used descaling agent or improves. Thus Electricity is saved. 

We request you to go through the enclosed brochure and  send us your valuable inquiries for our quote. Meantime, if you have the technical queries, please feel free to call us for the immediate assistance.  For details, please visit our website http://www.scaleseparator.com | for Video visit the link  https://www.youtube.com/watch?v=ko4tHEEjhC4|and for PPT visit the link https://drive.google.com/file/d/0B4Oe_aIQ9EvObHlTRmxPTXBWRms/view?usp=sharing 



With Warm Regards,
V.   P.    Jeyakumar.
Managing  Director.

HP: +91 91766 25082   Off. Ph - 9444 56 9900   Skype  ID: tiaanojk
Ph: +91 44 2278 1148  Fax: 2278 1362   Web :  www.tianode.com
E-mail :
managingdirector@tiaano.com  | tianode@gmail.com    
                 




Ti     Anode    Fabricators     Private     Limited.
#  -  48,  Noothanchary,  Madambakkam, Chennai - 126, INDIA.

GSTIN: 33AABCT9790N1ZN PAN: AABCT 9790N AADHAR: 7522 0783 3933

Thursday, 5 October 2017

Electrodes (Anodes and Cathodes) for Swimming pool chlorinator

Salt and electricity generates pure chlorine solution in a safe, simple and cost effective way to disinfect pools.  Recommended operating conditions of the pool is: 

Eatable Salt (sodium chloride) range of 2 to 6 grams per liter, average 4 Gpl that is 0.4% (less than 12% of sea water.   Pool temperature should be15-40°C, stabilizer levels of 30-50 ppm for outdoor facilities.


When the electrodes is energized by DC current, the catalyst react with the sodium chloride and water molecules at the anode and cathode surfaces to generate the chlorine disinfectant in the form of hypochlorous acid and sodium hypochlorite in the pool water.  When the chlorine kills the pathogens and oxidizes organics or contaminants, chlorine remains returns to the native state as salt (NaCl) in water as a recycling process.

Since the 1999 Tiaano offer titanium electrodes to worldwide swimming pool equipment manufacturers for swimming pool Electrochlorinators.  Our electrodes are showing outstanding performance in self-cleaning product based on current reversal technology.  The versatility of the product allows for use in residential, spa and commercial applications. 

Typical 3-5 year chlorinator life leads lesser amount of pool store since the disinfectant is made on-site.  Electrodes are made from Titanium Grade 1 sheet and mesh as per ASTM B 265, coated with platinum group precious metal oxide. 




With Warm Regards,
V.   P.    Jeyakumar.
Managing  Director.

HP: +91 91766 25082   Off. Ph - 9444 56 9900   Skype  ID: tiaanojk
Ph: +91 44 2278 1148  Fax: 2278 1362   Web :  www.tianode.com
E-mail : 
managingdirector@tiaano.com  | tianode@gmail.com    
Profile  :   http://www.tianode.com/images/Profile-TiAnode.pdf         
           
Ti     Anode    Fabricators     Private     Limited.
#  -  48,  Noothanchary,  Madambakkam, Chennai - 126, INDIA.
GSTIN: 33AABCT9790N1ZN PAN: AABCT 9790N AADHAR: 7522 0783 3933

Friday, 15 September 2017

PLATINISED ANODES


Platinum is widely used as electrodes in metal finishing industries, having special chemical & physical properties like high corrosion resistance, thermal conductivity and catalytic nature.  Being a very expensive metal, instead of using solid form, platinum is deposited on the surface of titanium or niobium, occasionally on molybdenum by micron level layer. 


 Electrodes [Anodes or Cathodes] are available with hanging hook, frame or band in the form of sheet, mesh, pipe, wire, rod and custom built.  Platinised titanium anode is used in electrolytes having no fluoride. Platinised niobium anodes are used in electrolytes having fluoride, where we need better conduction (its conductivity is three times of titanium)  and  also it is suitable for Sulphuric acid chromium plating bath operated at current density greater than 75A / dm². 

      


Platinised titanium / niobium anodes are having the advantages of Low weight - good current resistance; Long life operation - maintenance free;      Economical - due to low platinum requirements; High dimensional stability and low resistance; Highly suitable as auxiliary anodes of complex geometrical shapes. Visit our site www.ptanode.com to know more about platinized titanium, niobium, tantalum and molybdenum anodes.




  

With Warm Regards,
V.   P.    Jeyakumar.
Managing  Director.

HP: +91 91766 25082   Off. Ph - 9444 56 9900   Skype  ID: tiaanojk
Ph: +91 44 2278 1148  Fax: 2278 1362   Web :  www.tianode.com
E-mail :
managingdirector@tiaano.com  | tianode@gmail.com    
Profile  :   http://www.tianode.com/images/Profile-TiAnode.pdf                    
 




 \Ti     Anode    Fabricators     Private     Limited.
#  -  48,  Noothanchary,  Madambakkam, Chennai - 126, INDIA.
GSTIN: 33AABCT9790N1ZN PAN: AABCT 9790N AADHAR: 7522 0783 3933


Sunday, 20 August 2017

Scale Remover for cooling tower Water distribution system

Tiaano ventured and developed a Electrolytic Scale Remover (ElSr); without adding chemicals, it generates disinfectant insitu and remove the scale by electrolytic operation - mitigate the scaling, corrosion, bio-fouling & bacterial infection in cooling tower Water distribution system.  ElSr produces Oxidants in the water; Oxidants prevents the Corrosion, Bio-fouling, Scaling, Micro-Organism growth & spread of airborne bacteria. 

Scale / Slime fouling on Condenser results reduction in heat transfer.  One mm thick of scaling  will cause 30% more energy consumption.  Because of Ionization in ElSr, scale precipitation occurs; once the scale precipitated, it never adheres to the Condensers / cooling tower Water distribution system – it leads no further scale build up, slowly the existing scales also peels out in due course.  Resulting maintain ‘DELTA T’ as it is when you used descaling agent or improves ‘DELTA T’. Thus Electricity is saved. 

Passing DC current from positive element to the negative element, it creates high pH in the vicinity of the negative.  High pH causes scale to be deposited in the reactor.  The water is not soft at the outlet of the ElSr, but the scale forming ions has been reduced to a level that prevents the precipitation in cooling tower Water distribution system. ElSr will precipitate all scale forming ions, not just magnesium and calcium but other ions that are susceptible to dropping out the liquid at high pH Viz., Silica, Ferum, Manganese etc.
 The reaction in the chamber is   Cl -   +   H +   à   HCl       and then       HCl + HCl à  Cl2 + H2
 ElSr removes suspended solids automatically and continually through its inbuilt micron filter.   Savings in feed water, because reduction in water bleed.  Modular system is designed and available according to the cooling tower chiller capacity like 200 TR, 300 TR, 400 TR, 600 TR, 800 TR, 900 TR, 1200 TR & 1600 TR.  For more details, please visit our website http://www.scaleseparator.com




With Warm Regards,
V.   P.    Jeyakumar.
Managing  Director.

HP: +91 91766 25082   Off. Ph - 9444 56 9900   Skype  ID: tiaanojk
Ph: +91 44 2278 1148  Fax: 2278 1362   Web :  www.tianode.com
E-mail :
managingdirector@tiaano.com  | tianode@gmail.com    
           


Ti     Anode    Fabricators     Private     Limited.
#  -  48,  Noothanchary,  Madambakkam, Chennai - 126, INDIA.
GSTIN: 33AABCT9790N1ZN PAN: AABCT 9790N AADHAR: 7522 0783 3933 



Friday, 14 July 2017

TITANIUM Anodes & NICKEL Cathodes for CHLOR-ALKALI INDUSTRY



Tiaano®  a  leading  design and fabrication  company  established  in 1992 with well-equipped in plant facilities and qualified engineers, delivers DSA Titanium anodes and Nickel cathodes – both Refurbishment, Recoated and Zero gap Retrofitting by using Precious metal oxides of… Iridium, Ruthenium, Palladium etc. / ENGINEERING equipment and TURNKEY projects from the single platform by using inert metals.

   
Ø  Tiaano has been undertaking refurbishment and recoating chlor alkali electrodes since 1994.
Ø  Tiaano’s coatings are working more than a decades in…
o   UHDE / UHDENORA / DENORA / CEC’s Cells.
o   INEOs / ICI’s Cells
o   ELTECH / OXYTECH / DENORATECH’s Cells

Ø  Undertaking the refurbishment and recoating of anode
Coatings warranty starts from minimum of 6 years,   maximum 10 years according to the current density.  
Ø  Tiaano preparing Metal Oxides in its own refinery  from the precious metal sponge.
Ø  Servicing to the worldwide chlor alkali industries
Ø  including USA, IRAN, UAE, SAUDI ARABIA & INDIA. 


Reactors, Pressure vessels, Storage tanks, Column, Blowers, Mixers, Anolyte & Catholyte headers, Pumps, Valves, Pipe fittings, Thermowells and Fasteners by using inert metals of Titanium, Nickel, Monel, Tantalum, Niobium, Zirconium, Hastelloy, Duplex SS, Molybdenum & their alloys.


With Warm Regards,
V.   P.    Jeyakumar.
Managing  Director.

HP: +91 91766 25082   Off. Ph - 9444 56 9900   Skype  ID: tiaanojk
Ph: +91 44 2278 1148  Fax: 2278 1362   Web :  www.tianode.com
E-mail :
managingdirector@tiaano.com  | tianode@gmail.com    
           
Ti     Anode    Fabricators     Private     Limited.
#  -  48,  Noothanchary,  Madambakkam, Chennai - 126, INDIA.
GSTIN: 33AABCT9790N1ZN PAN: AABCT 9790N AADHAR: 7522 0783 3933 


Removal of scale in Cooling Tower circuit by chemical free scale separation- 'Electrolytic Scale Remover'

Tiaano ventured and developed a Electrolytic Scale Remover (ElSr).  It removes the scale by electrolytic operation with out adding chemica...